ROMEG - DYNAMIC LASER MEASUREMENTS OF WIND TURBINES

ROMEG M 20 G is a laser device for geometry measurement of rotors of wind turbines.

 

The ROMEG measurement is a laser-based Procedere for the verification of the dynamic and aerolastic behavior of the rotor and the whole turbine.
 
ROMEG can detect aerodynamically excited imbalances and indicate mass excited imbalances.

 

 Measurements are taken with the turbine in regular Operation.

Functions of the romeg system

The following parameters and functions are measured by ROMEG System:

  • Relative Blade angle -  The main function of the ROMEG system is the measuring and determining of the relative blade angle deviations. 
  • Detection of mass imbalances 
  • Tower vibrations -  The oscillation pattern of the axial tower movement is a good indicator for the evaluation of the detected blade angle deviations
  • Vibration analysis of the tower movement
  • Tower clearance 

MEASUREMENT PARAMETERS

relative blade angle

Relative blade angle

radial sharing

Radial sharing

Tower movement

Tower movement

Tower clearance

Tower clearance

Twist angle

Twist angle


advantages of using romeg

  • The laser measurements take place on the running turbine under real operating conditions.
  • Results are quickly available on site and can be used immediately for optimizing the turbine.
  • No loss of yield due to downtimes.
  • By comparing the vibration pattern before and after the correction, the success of the optimization is immediately visible and provable

WHY MEASURE?

In contrast to an imbalanced turbine, a turbine with well-balanced rotor shows the following attributes:

  • Better performance/higher yield
  • Higher availability 
  • Longer service-life of turbine
  • Less system loads
  • Reduced maintenance costs
  • Lower acoustic emission

Our statistics

According to our data of measuring more than 2 000 wind turbines:

statistics of aerodynamicaly imbalanced turbines

our certificate of Approval

The plausibility of ROMEG system as a measuring system for the determination of aerodynamic imbalances was first approved by  DEWI-OCC on 09.12.2014 and was again approved by UL / DEWI-OCC on 10.10.2019.

Download
Plausibility analysis of measurement system ROMEG
Plausibility analysis of measurement system ROMEG-M20 G
W0346_S13003028-4-en-R0.pdf
Adobe Acrobat Dokument 128.5 KB